U Pipe Solar Collector
U Pipe Solar Collector
Feedback

U Pipe Solar Collector

Characteristics
The U type solar collector are always connected with existing heating supply device. The selective coating of the evacuated tube converts solar energy into heat energy and transfers heat to metal U tube by the aluminum fin.The liquid (usually glycol-water antifreeze mixture) in the metal U tube is heater, and conducts the heat energy to the water inside the storage tank through plate exchanger or internal spiral coiler.



Technical Parameters:
Manifold(interior): red copper
Manifold(exterior): aluminum alloy
U Pipe: diameter 8mm thickness/ 0.6mm /red copper
Aluminium fin: 1600 mm full length
Heat insulation layer: Eco-friendly rockwool 50mm
Vacuum tube: 58*1800mm
SS-CU-AIN/ALN coating
Bracket: Aluminum alloy 1800mm
0-50 degree
Hail resistance: 25mm
Max pressure: 6 bar
Anti-freezing: > -35 ℃  
Daily efficiency: ≥55%
Parameter Table-1


Type
Area(M2) Vacuum tube
Qty(pcs)
Length/Width/Height(mm) GrossWeight (KG) 20GP/40GP/40HQ  Loading Qty(sets)
DIYI-U01-10 0.991 10 1660*920*150 26.7* 72/156/176
DIYI-U01-15 1.492 15 1660*1270*150 38.3 52/112/126
DIYI-U01-20 1.992 20 1660*1970*150 50.6 40/86/98
DIYI-U01-25 2.493 25 1660*1970*150 63.3 32/70/80
DIYI-U01-30 2.993 30 1660*2320*150 75 28/58/66
Vacuum tube size: 58*1800mm

Remark

  1. Manifold Connections(inch):3/4
  2. Max.service temperature: 95℃
  3. Max.stagnation temperature:200.3℃
  4. Flow range recommendation(50-150L/m2h)

 

U Pipe Solar Collector

Characteristics
The U type solar collector are always connected with existing heating supply device. The selective coating of the evacuated tube converts solar energy into heat energy and transfers heat to metal U tube by the aluminum fin.The liquid (usually glycol-water antifreeze mixture) in the metal U tube is heater, and conducts the heat energy to the water inside the storage tank through plate exchanger or internal spiral coiler.



Technical Parameters:
Manifold(interior): red copper
Manifold(exterior): aluminum alloy
U Pipe: diameter 8mm thickness/ 0.6mm /red copper
Aluminium fin: 1600 mm full length
Heat insulation layer: Eco-friendly rockwool 50mm
Vacuum tube: 58*1800mm
SS-CU-AIN/ALN coating
Bracket: Aluminum alloy 1800mm
0-50 degree
Hail resistance: 25mm
Max pressure: 6 bar
Anti-freezing: > -35 ℃  
Daily efficiency: ≥55%
Parameter Table-1


Type
Area(M2) Vacuum tube
Qty(pcs)
Length/Width/Height(mm) GrossWeight (KG) 20GP/40GP/40HQ  Loading Qty(sets)
DIYI-U01-10 0.991 10 1660*920*150 26.7* 72/156/176
DIYI-U01-15 1.492 15 1660*1270*150 38.3 52/112/126
DIYI-U01-20 1.992 20 1660*1970*150 50.6 40/86/98
DIYI-U01-25 2.493 25 1660*1970*150 63.3 32/70/80
DIYI-U01-30 2.993 30 1660*2320*150 75 28/58/66
Vacuum tube size: 58*1800mm

Remark

  1. Manifold Connections(inch):3/4
  2. Max.service temperature: 95℃
  3. Max.stagnation temperature:200.3℃
  4. Flow range recommendation(50-150L/m2h)

 